{"id":4325,"date":"2023-07-21T02:17:35","date_gmt":"2023-07-21T02:17:35","guid":{"rendered":"https:\/\/seditesa.es\/?p=4325"},"modified":"2024-01-11T06:09:17","modified_gmt":"2024-01-11T06:09:17","slug":"para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect","status":"publish","type":"post","link":"https:\/\/seditesa.es\/en\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/","title":{"rendered":"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Antes de leer este art\u00edculo te recomendamos que leas <strong><a href=\"https:\/\/seditesa.es\/valvula-reductora-de-presion-de-tlv-cospect\/\" target=\"_blank\" rel=\"noreferrer noopener\">este otro<\/a><\/strong> en el que se hace una introducci\u00f3n los problemas m\u00e1s comunes que resuelve una v\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT. Hoy vamos a poner varios ejemplos pr\u00e1cticos m\u00e1s de problemas comunes y las soluciones que aplica TLV COSPECT. Recuerda que si tienes cualquier duda puedes ponerte en <strong><a href=\"https:\/\/seditesa.es\/contacto\/\" target=\"_blank\" rel=\"noreferrer noopener\">contacto con Seditesa<\/a><\/strong>.<\/p>\n\n\n\t\t\t\t<div class=\"wp-block-uagb-table-of-contents uagb-toc__align-left uagb-toc__columns-1  uagb-block-ddd98bfd      \"\n\t\t\t\t\tdata-scroll= \"1\"\n\t\t\t\t\tdata-offset= \"30\"\n\t\t\t\t\tstyle=\"\"\n\t\t\t\t>\n\t\t\t\t<div class=\"uagb-toc__wrap\">\n\t\t\t\t\t\t<div class=\"uagb-toc__title\">\n\t\t\t\t\t\t\t<strong>V\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT<\/strong>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"uagb-toc__list-wrap \">\n\t\t\t\t\t\t<ol class=\"uagb-toc__list\"><li class=\"uagb-toc__list\"><a href=\"#primer-ejemplo-de-problema-que-soluciona-la-v\u00e1lvula-reductora-de-presi\u00f3n-de-vapor-de-tlv-cospect-procesamiento-de-carne\" class=\"uagb-toc-link__trigger\">Primer ejemplo de problema que soluciona la v\u00e1lvula reductora de presi\u00f3n de vapor de TLV COSPECT: Procesamiento de carne<\/a><ul class=\"uagb-toc__list\"><li class=\"uagb-toc__list\"><a href=\"#ejemplo-en-industria-de-procesamiento-de-carne\" class=\"uagb-toc-link__trigger\">Ejemplo en industria de procesamiento de carne<\/a><\/li><\/ul><\/li><li class=\"uagb-toc__list\"><a href=\"#segundo-ejemplo-de-problema-que-soluciona-la-reductora-de-presi\u00f3n-de-vapor-de-tlv-cospect-ca\u00eddas-en-las-fluctuaciones-de-temperatura-de-10\u00bac-y-hasta-con-2\u00bac\" class=\"uagb-toc-link__trigger\">Segundo ejemplo de problema que soluciona la reductora de presi\u00f3n de vapor de TLV COSPECT: Ca\u00eddas en las fluctuaciones de temperatura de 10\u00baC y hasta con 2\u00baC<\/a><ul class=\"uagb-toc__list\"><li class=\"uagb-toc__list\"><a href=\"#ejemplo-de-hule-industrial\" class=\"uagb-toc-link__trigger\">Ejemplo de hule Industrial<\/a><\/li><\/ul><\/li><\/ul><\/li><li class=\"uagb-toc__list\"><a href=\"#otros-problemas-comunes-que-soluciona-la-v\u00e1lvula-reductora-de-presi\u00f3n-de-vapor-de-tlv-cospect\" class=\"uagb-toc-link__trigger\">Otros problemas comunes que soluciona la v\u00e1lvula reductora de presi\u00f3n de vapor de TLV COSPECT<\/a><ul class=\"uagb-toc__list\"><li class=\"uagb-toc__list\"><a href=\"#el-mantenimiento-es-muy-problem\u00e1tico\" class=\"uagb-toc-link__trigger\">El mantenimiento es muy problem\u00e1tico<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list\"><a href=\"#la-configuraci\u00f3n-de-la-tuber\u00eda-es-muy-complicada\" class=\"uagb-toc-link__trigger\">La configuraci\u00f3n de la tuber\u00eda es muy complicada<\/a><ul class=\"uagb-toc__list\"><li class=\"uagb-toc__list\"><a href=\"#es-necesario-equipo-adicional-para-proteger-la-prv-del-condensado-y-las-incrustaciones\" class=\"uagb-toc-link__trigger\">Es necesario equipo adicional para proteger la PRV del condensado y las incrustaciones.<\/a><li class=\"uagb-toc__list\"><li class=\"uagb-toc__list\"><a href=\"#dise\u00f1ada-para-dar-reflejar-las-opiniones-de-los-usuarios-en-el-producto-final\" class=\"uagb-toc-link__trigger\">Dise\u00f1ada para dar reflejar las opiniones de los usuarios en el producto final<\/a><\/ul><\/ul><\/ul><\/ul><\/ol>\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\n\n\n<h2 class=\"wp-block-heading\"><br>Primer ejemplo de problema que soluciona la v\u00e1lvula reductora de presi\u00f3n de vapor de TLV COSPECT: Procesamiento de carne<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/procesadora-de-carne.jpg\" alt=\"Procesadora de carne\" class=\"wp-image-4326\" width=\"302\" height=\"243\"\/><figcaption class=\"wp-element-caption\">Procesadora de carne<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Normalmente hay que hacer frecuentes ajustes en la presi\u00f3n del vapor, pero con la reductora de presi\u00f3n de vapor TLV COSPECT los ajustes se reducen a pr\u00e1cticamente cero. Una vez cada 10 a\u00f1os. No hay mantenimiento.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ejemplo en industria de procesamiento de carne<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Producto:<\/strong> Salchicha y\/o jam\u00f3n.<\/li>\n\n\n\n<li><strong>Equipo:<\/strong> Zona de ahumado, tuber\u00eda de transporte de vapor.<\/li>\n\n\n\n<li><strong>Operaci\u00f3n<\/strong>: Operaci\u00f3n por tiempos (batch) \/ Operaci\u00f3n continua.<\/li>\n\n\n\n<li><strong>Modelo Utilizado:<\/strong> COS-16, COSR-16, MC-COS-16; Presi\u00f3n primaria 7 barg.<\/li>\n\n\n\n<li><strong>Presi\u00f3n de ajuste: <\/strong>1,9 &#8211; 3,0 barg.<\/li>\n\n\n\n<li><strong>A\u00f1os de servicio:<\/strong> Desde hace 18 a\u00f1os.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Este es la opini\u00f3n de un profesional del sector despu\u00e9s de haber utilizado durante a\u00f1os la v\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00ab<em>Las PRVs que utilizamos en un principio siempre estaban teniendo problemas y fueron un gran dolor de cabeza para nosotros. La presi\u00f3n de ajuste aumentaba r\u00e1pidamente, por lo que fue necesario realizar ajustes diariamente, y a\u00fan cuando no trabajaban, nos vimos obligados a desmontar las mismas PRVs. La remoci\u00f3n de los diafragmas revelaron que hab\u00eda corrosi\u00f3n, y terminamos teniendo que remplazarlos cada a\u00f1o. Adem\u00e1s de eso, todas las PRVs fueron instaladas a grandes alturas, por lo que trabajar en ellas involucr\u00f3 una gran cantidad de tiempo, esfuerzo y dinero.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Fue en este momento decidimos darle a la v\u00e1lvula reductora de presi\u00f3n de vapor de TLV COSPECT<\/em> <em>una oportunidad. Todos los problemas que hab\u00edamos tenido simplemente desaparecieron.<\/em> <em>En particular, cuando cambiamos la caldera de tipo fuego-directo a una caldera de un solo paso, tuvimos muchos problemas con las PRVs que no eran TLV. La COSPECT, sin embargo, ha estado operando continuamente durante los 18 a\u00f1os transcurridos desde entonces, y no ha tenido absolutamente ninguna necesidad de mantenimiento.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Han pasado 18 a\u00f1os desde que por primera vez iniciamos la utilizaci\u00f3n de la v\u00e1lvula reductora de presi\u00f3n de vapor de TLV COSPECT, y simplemente no hay sustituto para la sensaci\u00f3n de seguridad que la nos ha dado.<\/em>\u00bb<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Segundo ejemplo de problema que soluciona la reductora de presi\u00f3n de vapor de TLV COSPECT: Ca\u00eddas en las fluctuaciones de temperatura de 10\u00baC y hasta con 2\u00baC<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/caidas-en-las-fluctuaciones-de-temperatura.jpg\" alt=\"Ca\u00eddas en las fluctuaciones de temperatura\" class=\"wp-image-4330\" width=\"346\" height=\"243\"\/><figcaption class=\"wp-element-caption\">Ca\u00eddas en las fluctuaciones de temperatura<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">La la reductora de presi\u00f3n de vapor de TLV COSPECT puede solucionar los defectos la estabilizaci\u00f3n de la presi\u00f3n secundaria.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ejemplo d<strong>e hule Industrial<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Producto:<\/strong> Bandas de goma y\/o calzado.<\/li>\n\n\n\n<li><strong>Equipo: <\/strong>Prensa Multi-etapas.<\/li>\n\n\n\n<li><strong>Operaci\u00f3n: <\/strong>Operaci\u00f3n por tiempos (batch).<\/li>\n\n\n\n<li><strong>Modelo Utilizado:<\/strong> COS-16.<\/li>\n\n\n\n<li><strong>Condiciones de Operaci\u00f3n:<\/strong> Presi\u00f3n primaria 8 barg \/ Presi\u00f3n de ajuste 5 barg.<\/li>\n\n\n\n<li><strong>A\u00f1os de Servicio: <\/strong>Desde hace 19 a\u00f1os.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Opiniones de un jefe de producto de la divisi\u00f3n administraci\u00f3n de producci\u00f3n:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u00abEn el pasado, el principal problema que tuvimos con las PRVs que no eran TLV fue que la presi\u00f3n secundaria era inestable, lo cual llev\u00f3 a las fluctuaciones de temperatura de las prensas y provoc\u00f3 una disminuci\u00f3n de la calidad del producto. En particular, esto se hizo notoriamente evidente cuando primero cambiamos a la caldera de un solo paso que utilizamos ahora. Las presiones reales fluctuaron desde la presi\u00f3n de ajuste en alrededor de 0,2 &#8211; 0,3 bar, y tambi\u00e9n ocurrieron fluctuaciones de temperatura de alrededor de 10\u00baC.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Sin embargo, desde la instalaci\u00f3n de la v\u00e1lvula reductora de presi\u00f3n de vapor de TLV COSPECT, la presi\u00f3n se mantiene estable en la presi\u00f3n de ajuste y los problemas de calidad de producto por temperatura inducida sol\u00eda ocurrir 2-3 veces por mes han sido completamente eliminados. Hubo un per\u00edodo durante el cual una vez m\u00e1s utilizamos PRVs que no eran TLV debido a las limitaciones presupuestarias, pero el resultado fue presi\u00f3n inestable y la repetici\u00f3n de problemas con la afectaci\u00f3n de la calidad del producto. Esto nos llev\u00f3 a reconocer una vez m\u00e1s la alta fiabilidad de la COSPECT, y no hemos utilizado nada m\u00e1s que la v\u00e1lvula reductora de presi\u00f3n de vapor de TLV COSPECT<\/em> <em>desde entonces.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Adem\u00e1s, como ofrece ahorro de espacio debido a su construcci\u00f3n compacta con filtro integral, separador y <a href=\"https:\/\/www.elmagacin.com\/para-que-se-utilizan-los-purgadores-de-vapor-de-tlv\/\" target=\"_blank\" rel=\"noreferrer noopener\">purgador<\/a> de vapor, en adici\u00f3n a sus otras caracter\u00edsticas dise\u00f1adas desde el punto de vista del usuario en planta, la COSPECT es altamente apreciada por las personas encargadas de nuestras plantas de procesamiento.\u00bb<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Otros problemas comunes que soluciona la v\u00e1lvula reductora de presi\u00f3n de vapor de TLV COSPECT<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/mantenimiento-problematico.jpg\" alt=\"Mantenimiento problem\u00e1tico\" class=\"wp-image-4331\" width=\"201\" height=\"174\"\/><figcaption class=\"wp-element-caption\">Mantenimiento problem\u00e1tico<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">El mantenimiento es muy problem\u00e1tico<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si el diafragma se oxida o existe acumulaci\u00f3n de adhesiones en el pist\u00f3n debido al condensado, el ox\u00eddo o las incrustaciones ingresan a la v\u00e1lvula reductora de presi\u00f3n, la capacidad de controlar la presi\u00f3n se puede perder presi\u00f3n (entre otras cosas).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cada vez que ocurre un problema, es necesario desmontar y limpiar la PRV, pero esto es problem\u00e1tico, porque los empaques o juntas pueden desprenderse en pedazos y no pueden ser reutilizadas, tambi\u00e9n se requieren muchas herramientas especiales. Adicionalmente esto requiere de una gran cantidad de tiempo y muchas horas.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">La configuraci\u00f3n de la tuber\u00eda es muy complicada<\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/configuracion-de-tuberia.jpg\" alt=\"Configuraci\u00f3n de tuber\u00eda\" class=\"wp-image-4332\" width=\"497\" height=\"289\"\/><figcaption class=\"wp-element-caption\">Configuraci\u00f3n de tuber\u00eda<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">El interior de la PRV esta conformado por muchas partes complicadas, tales como un piloto y v\u00e1lvula principal. El condensado, la oxidaci\u00f3n y las incrustaciones contenidas en la tuber\u00eda de vapor causan desgaste y goteo, y la acumulaci\u00f3n en las partes interiores alteraran considerablemente la durabilidad de la PRV.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Es necesario equipo adicional para proteger la PRV del condensado y las incrustaciones.<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Para prevenir da\u00f1os, los fabricantes recomiendan que las PRVs sean protegidas del condensado y las incrustaciones mediante la instalaci\u00f3n de equipos adicionales, tales como un filtro, separador y trampa de vapor. Como resultado de ello, la conformaci\u00f3n de la tuber\u00eda llega a ser complicada, necesita de mucho trabajo adicional, y requiere un gran espacio de instalaci\u00f3n.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La v\u00e1lvula reductora de presi\u00f3n de vapor TLV, nacida de las opiniones de personal de planta (usuarios), es la respuesta a todos estos problemas.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"822\" height=\"784\" src=\"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg\" alt=\"V\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT\" class=\"wp-image-4333\"\/><figcaption class=\"wp-element-caption\">V\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT<\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Dise\u00f1ada para dar reflejar las opiniones de los usuarios en el producto final<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Estandarizaci\u00f3n de los tama\u00f1os de birlos, uso de empaques de resina de fl\u00faor o componentes internos fabricados en acero inoxidable son algunas de las sugerencias que ha recogido TLV de las opiniones de sus usuarios. En la actualidad, estas caracter\u00edsticas y otras muchas est\u00e1n en el camino a convertirse en normas en el sector de las v\u00e1lvulas reductoras de presi\u00f3n, pero la COSPECT las ha ofrecido desde que fue desarrollada por primera vez en 1985. Es simplemente avanzada a su tiempo. Todas las caracter\u00edsticas necesarias en un solo producto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Contenido relacionado con la v\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT que tambi\u00e9n pueda interesarte:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/seditesa.es\/como-ahorrar-energia-aislando-las-valvulas-un-metodo-eficaz-y-rentable\/\" target=\"_blank\" rel=\"noreferrer noopener\">C\u00f3mo ahorrar energ\u00eda aislando las v\u00e1lvulas<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/seditesa.es\/recuperacion-del-condensado\/\" target=\"_blank\" rel=\"noreferrer noopener\">Recuperaci\u00f3n del condensado<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/seditesa.es\/purgadores-de-vapor-seleccion-y-tipos-seditesa-tlv\/\" target=\"_blank\" rel=\"noreferrer noopener\">Purgadores de vapor<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/b7AA92Anz3g\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe>\n","protected":false},"excerpt":{"rendered":"<p>Problemas comunes y las soluciones que aplica la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT teniendo en cuenta las opiniones del sector.<\/p>\n","protected":false},"author":8,"featured_media":4333,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"off","_et_pb_old_content":"","_et_gb_content_width":"","_uag_custom_page_level_css":"","footnotes":""},"categories":[7],"tags":[108],"class_list":["post-4325","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-valvuleria-y-accesorios","tag-spanish"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT<\/title>\n<meta name=\"description\" content=\"Problemas comunes y las soluciones para que sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT, teniendo en cuenta opiniones de clientes.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT\" \/>\n<meta property=\"og:description\" content=\"Problemas comunes y las soluciones que aplica la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT teniendo en cuenta las opiniones del sector.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/\" \/>\n<meta property=\"og:site_name\" content=\"Seditesa\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-21T02:17:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-11T06:09:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"822\" \/>\n\t<meta property=\"og:image:height\" content=\"784\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Daniel\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT\" \/>\n<meta name=\"twitter:description\" content=\"Problemas comunes y las soluciones que aplica la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT teniendo en cuenta las opiniones del sector.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg\" \/>\n<meta name=\"twitter:creator\" content=\"@Seditesa\" \/>\n<meta name=\"twitter:site\" content=\"@Seditesa\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Daniel\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/\"},\"author\":{\"name\":\"Daniel\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/#\\\/schema\\\/person\\\/ae6adeb6df08650023df594e7cf27b51\"},\"headline\":\"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT\",\"datePublished\":\"2023-07-21T02:17:35+00:00\",\"dateModified\":\"2024-01-11T06:09:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/\"},\"wordCount\":1295,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/seditesa.es\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg\",\"keywords\":[\"spanish\"],\"articleSection\":[\"VALVULER\u00cdA Y ACCESORIOS\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/\",\"url\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/\",\"name\":\"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/seditesa.es\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg\",\"datePublished\":\"2023-07-21T02:17:35+00:00\",\"dateModified\":\"2024-01-11T06:09:17+00:00\",\"description\":\"Problemas comunes y las soluciones para que sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT, teniendo en cuenta opiniones de clientes.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/#primaryimage\",\"url\":\"https:\\\/\\\/seditesa.es\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg\",\"contentUrl\":\"https:\\\/\\\/seditesa.es\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg\",\"width\":822,\"height\":784,\"caption\":\"V\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/seditesa.es\\\/en\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/#website\",\"url\":\"https:\\\/\\\/seditesa.es\\\/\",\"name\":\"Seditesa\",\"description\":\"Tecnolog\u00eda del vapor\",\"publisher\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/seditesa.es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/#organization\",\"name\":\"Seditesa\",\"url\":\"https:\\\/\\\/seditesa.es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/seditesa.es\\\/wp-content\\\/uploads\\\/2022\\\/11\\\/Seditesa-logotipo-final.png\",\"contentUrl\":\"https:\\\/\\\/seditesa.es\\\/wp-content\\\/uploads\\\/2022\\\/11\\\/Seditesa-logotipo-final.png\",\"width\":302,\"height\":100,\"caption\":\"Seditesa\"},\"image\":{\"@id\":\"https:\\\/\\\/seditesa.es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/Seditesa\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/seditesa.es\\\/#\\\/schema\\\/person\\\/ae6adeb6df08650023df594e7cf27b51\",\"name\":\"Daniel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/37d5d65f756ddb97acc8e50802590f256afd6538dc919dc4cdc69b8b7af4c16b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/37d5d65f756ddb97acc8e50802590f256afd6538dc919dc4cdc69b8b7af4c16b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/37d5d65f756ddb97acc8e50802590f256afd6538dc919dc4cdc69b8b7af4c16b?s=96&d=mm&r=g\",\"caption\":\"Daniel\"},\"url\":\"https:\\\/\\\/seditesa.es\\\/en\\\/author\\\/daniel\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT","description":"Problemas comunes y las soluciones para que sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT, teniendo en cuenta opiniones de clientes.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/","og_locale":"en_US","og_type":"article","og_title":"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT","og_description":"Problemas comunes y las soluciones que aplica la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT teniendo en cuenta las opiniones del sector.","og_url":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/","og_site_name":"Seditesa","article_published_time":"2023-07-21T02:17:35+00:00","article_modified_time":"2024-01-11T06:09:17+00:00","og_image":[{"width":822,"height":784,"url":"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg","type":"image\/jpeg"}],"author":"Daniel","twitter_card":"summary_large_image","twitter_title":"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT","twitter_description":"Problemas comunes y las soluciones que aplica la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT teniendo en cuenta las opiniones del sector.","twitter_image":"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg","twitter_creator":"@Seditesa","twitter_site":"@Seditesa","twitter_misc":{"Written by":"Daniel","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/#article","isPartOf":{"@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/"},"author":{"name":"Daniel","@id":"https:\/\/seditesa.es\/#\/schema\/person\/ae6adeb6df08650023df594e7cf27b51"},"headline":"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT","datePublished":"2023-07-21T02:17:35+00:00","dateModified":"2024-01-11T06:09:17+00:00","mainEntityOfPage":{"@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/"},"wordCount":1295,"commentCount":0,"publisher":{"@id":"https:\/\/seditesa.es\/#organization"},"image":{"@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/#primaryimage"},"thumbnailUrl":"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg","keywords":["spanish"],"articleSection":["VALVULER\u00cdA Y ACCESORIOS"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/","url":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/","name":"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT","isPartOf":{"@id":"https:\/\/seditesa.es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/#primaryimage"},"image":{"@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/#primaryimage"},"thumbnailUrl":"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg","datePublished":"2023-07-21T02:17:35+00:00","dateModified":"2024-01-11T06:09:17+00:00","description":"Problemas comunes y las soluciones para que sirve la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT, teniendo en cuenta opiniones de clientes.","breadcrumb":{"@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/#primaryimage","url":"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg","contentUrl":"https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg","width":822,"height":784,"caption":"V\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT"},{"@type":"BreadcrumbList","@id":"https:\/\/seditesa.es\/para-que-sirve-la-valvula-reductora-de-presion-de-vapor-tlv-cospect\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/seditesa.es\/en\/home\/"},{"@type":"ListItem","position":2,"name":"Para qu\u00e9 sirve la v\u00e1lvula reductora de presi\u00f3n de vapor TLV COSPECT"}]},{"@type":"WebSite","@id":"https:\/\/seditesa.es\/#website","url":"https:\/\/seditesa.es\/","name":"Seditesa","description":"Tecnolog\u00eda del vapor","publisher":{"@id":"https:\/\/seditesa.es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/seditesa.es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/seditesa.es\/#organization","name":"Seditesa","url":"https:\/\/seditesa.es\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/seditesa.es\/#\/schema\/logo\/image\/","url":"https:\/\/seditesa.es\/wp-content\/uploads\/2022\/11\/Seditesa-logotipo-final.png","contentUrl":"https:\/\/seditesa.es\/wp-content\/uploads\/2022\/11\/Seditesa-logotipo-final.png","width":302,"height":100,"caption":"Seditesa"},"image":{"@id":"https:\/\/seditesa.es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/Seditesa"]},{"@type":"Person","@id":"https:\/\/seditesa.es\/#\/schema\/person\/ae6adeb6df08650023df594e7cf27b51","name":"Daniel","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/37d5d65f756ddb97acc8e50802590f256afd6538dc919dc4cdc69b8b7af4c16b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/37d5d65f756ddb97acc8e50802590f256afd6538dc919dc4cdc69b8b7af4c16b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/37d5d65f756ddb97acc8e50802590f256afd6538dc919dc4cdc69b8b7af4c16b?s=96&d=mm&r=g","caption":"Daniel"},"url":"https:\/\/seditesa.es\/en\/author\/daniel\/"}]}},"uagb_featured_image_src":{"full":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg",822,784,false],"thumbnail":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT-150x150.jpg",150,150,true],"medium":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT-300x286.jpg",300,286,true],"medium_large":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT-768x732.jpg",768,732,true],"large":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg",822,784,false],"1536x1536":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg",822,784,false],"2048x2048":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg",822,784,false],"et-pb-post-main-image":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT-400x250.jpg",400,250,true],"et-pb-post-main-image-fullwidth":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT-822x675.jpg",822,675,true],"et-pb-portfolio-image":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT-400x284.jpg",400,284,true],"et-pb-portfolio-module-image":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT-510x382.jpg",510,382,true],"et-pb-portfolio-image-single":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg",822,784,false],"et-pb-gallery-module-image-portrait":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT-400x516.jpg",400,516,true],"et-pb-post-main-image-fullwidth-large":["https:\/\/seditesa.es\/wp-content\/uploads\/2023\/07\/valvula-reductora-de-presion-de-vapor-TLV-COSPECT.jpg",822,784,false]},"uagb_author_info":{"display_name":"Daniel","author_link":"https:\/\/seditesa.es\/en\/author\/daniel\/"},"uagb_comment_info":0,"uagb_excerpt":"Problemas comunes y las soluciones que aplica la v\u00e1lvula reductora de presi\u00f3n de vapor COSPECT teniendo en cuenta las opiniones del sector.","_links":{"self":[{"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/posts\/4325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/comments?post=4325"}],"version-history":[{"count":1,"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/posts\/4325\/revisions"}],"predecessor-version":[{"id":7091,"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/posts\/4325\/revisions\/7091"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/media\/4333"}],"wp:attachment":[{"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/media?parent=4325"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/categories?post=4325"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/seditesa.es\/en\/wp-json\/wp\/v2\/tags?post=4325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}